ACP8820 + 2XACP8820X Optical Power Meter with Optical Head
ACP8820 + 2XACP8820X is an optical power meter with optical heads which offers superior performances in testing of DWDM components, AWG & PLC components, optical amplifiers, and other general purpose fiber optical test and measurement applications. It is designed especially for volume production line applications.
ACP8820 + 2XACP8820X Optical Power Meter is a high performance, small dimension, fast startup, affordable optical power meter family. It provides low power, high power, single channel and dual channel optical power meter modules options. AC Photonics also can provide high channel count solutions up to 16 channels.
Features
- High Performance
- Quick Startup
- Difference Power Range and Difference Channel Number Available
- Small Dimension
- Affordable Price
Applications
- WDM, AWG, PLC Components Insertion Loss, Return Loss Test
- Fiber Sensor, Fiber Cable Test
- PMD and PDL Measurement
- Fiber Optical, Telcom R and D Lab Test
Specifications
| Parameter | Unit | Specifications | |
|---|---|---|---|
| Model# | ACP8820 + ACP88201 | ACP8820 + 2XACP88201 | |
| Sensor Element | Single Channel InGaAs | Dual Channel InGaAs | |
| Wavelength Range | nm | 850 ~ 1700 | |
| Power Range | dBm | +3 ~ -85 | |
| Application Fiber Type | Standard SM and MM up to 62.5um core size | ||
| Uncertainty (accuracy) at Reference Condition | nm | ± 4% (1200 ~ 1610) | |
| Relative Uncertainty (accuracy) at Reference Condition | dB | < 0.02 (Typical) | |
| Linearity (power) | dB | ≤± 0.06 (1200nm ~ 1610nm, +0~ -60dBm) | |
| Return Loss | dB | > 40 | |
| Operating Temperature | °C | 0 to +40 | |
| Storage Temperature | °C | - 30 to +80 | |
| Recalibration Period | dB | 2 Years | |
| Package Dimensions (HxWxD) | mm | 200 x 105 x 250 | |
| Weight | kg | 6.5 | |
| Parameter | Specifications | ||
| Model# | ACP8820 + ACP88203 | ACP8820 + 2XACP88203 | |
| Sensor Element | Single Channel InGaAs | Dual Channel InGaAs | |
| Wavelength Range | nm | 850 ~ 1700 | |
| Power Range | dBm | +23 ~ -60 | |
| Application Fiber Type | Standard SM and MM up to 62.5um core size | ||
| Uncertainty (accuracy) at Reference Condition | nm | ± 4% (1200 ~ 1610) | |
| Relative Uncertainty (accuracy) at Reference Condition | dB | < 0.02 (Typical) | |
| Linearity (power) | dB | ≤± 0.06 (1200nm ~ 1610nm, +0~ -60dBm) | |
| Return Loss | dB | > 40 | |
| Operating Temperature | °C | 0 to +40 | |
| Storage Temperature | °C | - 30 to +80 | |
| Recalibration Period | 2 Years | ||
| Package Dimensions (HxWxD) | mm | 200 x 105 x 250 | |
| Weight | kg | 6.5 | |